Skip to content

Commit 9f4f01d

Browse files
committed
Templates update for nightly evcc-io/evcc@fcfacaf
1 parent 3db478c commit 9f4f01d

File tree

2 files changed

+80
-0
lines changed

2 files changed

+80
-0
lines changed

templates/nightly/de/meter/solaredge-hybrid-inverter.yaml

Lines changed: 40 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -160,6 +160,10 @@ render:
160160
port: 1502 # Port
161161
timeout: 10s # Zeitüberschreitung, optional
162162
capacity: 50 # Akkukapazität (kWh), optional
163+
maxchargepower: # Maximale Ladeleistung (W), Für erzwungenes Laden des Speichers. (optional)
164+
maxdischargepower: 5000 # Maximale Entladeleistung (W), Maximale Entladeleistung des Speichers. (optional)
165+
minsoc: 25 # Minimaler Ladestand (%), Untere Grenze beim Entladen der Batterie im normalen Betrieb (optional)
166+
maxsoc: 95 # Maximaler Ladestand (%), Oberes Limit beim Laden der Batterie aus dem Netz (optional)
163167
watchdog: 60s # Watchdog, optional
164168
params:
165169
- name: modbus
@@ -198,6 +202,42 @@ params:
198202
help:
199203
advanced: true
200204
optional: true
205+
- name: maxchargepower
206+
example:
207+
default:
208+
choice: []
209+
unit: W
210+
description: Maximale Ladeleistung
211+
help: Für erzwungenes Laden des Speichers.
212+
advanced: true
213+
optional: true
214+
- name: maxdischargepower
215+
example:
216+
default: 5000
217+
choice: []
218+
unit: W
219+
description: Maximale Entladeleistung
220+
help: Maximale Entladeleistung des Speichers.
221+
advanced: true
222+
optional: true
223+
- name: minsoc
224+
example: 25
225+
default:
226+
choice: []
227+
unit: '%'
228+
description: Minimaler Ladestand
229+
help: Untere Grenze beim Entladen der Batterie im normalen Betrieb
230+
advanced: true
231+
optional: true
232+
- name: maxsoc
233+
example: 95
234+
default:
235+
choice: []
236+
unit: '%'
237+
description: Maximaler Ladestand
238+
help: Oberes Limit beim Laden der Batterie aus dem Netz
239+
advanced: true
240+
optional: true
201241
- name: watchdog
202242
example:
203243
default: 60s

templates/nightly/en/meter/solaredge-hybrid-inverter.yaml

Lines changed: 40 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -160,6 +160,10 @@ render:
160160
port: 1502 # Port
161161
timeout: 10s # Timeout, optional
162162
capacity: 50 # Battery capacity (kWh), optional
163+
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
164+
maxdischargepower: 5000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
165+
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
166+
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
163167
watchdog: 60s # Watchdog, optional
164168
params:
165169
- name: modbus
@@ -198,6 +202,42 @@ params:
198202
help:
199203
advanced: true
200204
optional: true
205+
- name: maxchargepower
206+
example:
207+
default:
208+
choice: []
209+
unit: W
210+
description: Maximum charge power
211+
help: For forced charging of the battery.
212+
advanced: true
213+
optional: true
214+
- name: maxdischargepower
215+
example:
216+
default: 5000
217+
choice: []
218+
unit: W
219+
description: Maximum discharge power
220+
help: Maximum discharge power of the storage.
221+
advanced: true
222+
optional: true
223+
- name: minsoc
224+
example: 25
225+
default:
226+
choice: []
227+
unit: '%'
228+
description: Minimum charge
229+
help: Lower limit when discharging the battery in normal operation
230+
advanced: true
231+
optional: true
232+
- name: maxsoc
233+
example: 95
234+
default:
235+
choice: []
236+
unit: '%'
237+
description: Maximum charge
238+
help: Upper limit when charging the battery from the grid
239+
advanced: true
240+
optional: true
201241
- name: watchdog
202242
example:
203243
default: 60s

0 commit comments

Comments
 (0)