Heliotherm heat pump KNX gateway for Python 3.7 and 3.8.
Can be used to provide the different Heliotherm heat pump parameters as data points to the KNX bus.
- GitHub repo: https://github.com/dstrigl/htknx
- Free software: GNU General Public License v3
Warning:
Please note that any incorrect or careless usage of this application as well as errors in the implementation can damage your heat pump!
Therefore, the author does not provide any guarantee or warranty concerning to correctness, functionality or performance and does not accept any liability for damage caused by this application, examples or mentioned information.
Thus, use it on your own risk!
The following diagram shows the schematic view of a possible setup:
You can install or upgrade htknx with:
$ pip install htknx --upgrade
Or you can install from source with:
$ git clone https://github.com/dstrigl/htknx.git
$ cd htknx
$ python setup.py install
usage: htknx [-h] [--logging-config LOGGING_CONFIG] [config_file]
Heliotherm heat pump KNX gateway, v0.1.0.
https://github.com/dstrigl/htknx
positional arguments:
config_file the filename under which the gateway settings can be
found, default: htknx.yaml
optional arguments:
-h, --help show this help message and exit
--logging-config LOGGING_CONFIG
the filename under which the logging configuration can
be found, default: logging.conf
DISCLAIMER
----------
Please note that any incorrect or careless usage of this program as well as
errors in the implementation can damage your heat pump!
Therefore, the author does not provide any guarantee or warranty concerning
to correctness, functionality or performance and does not accept any liability
for damage caused by this program or mentioned information.
Thus, use it on your own risk!
$ htknx /home/pi/my-htknx.yaml
HTHEATPUMP: load parameter definitions from: /home/pi/venv/htknx/lib/python3.7/site-packages/htheatpump-1.3.1-py3.7.egg/htheatpump/htparams.csv
Namespace(config_file='/home/pi/my-htknx.yaml', logging_config='/home/pi/prog/htknx/htknx/logging.conf')
2021-01-27 17:14:35,736 INFO [htknx.__main__|main_async]: Load settings from '/home/pi/my-htknx.yaml'.
2021-01-27 17:14:36,394 INFO [htknx.__main__|main_async]: Start Heliotherm heat pump KNX gateway v0.1.0.
2021-01-27 17:14:36,505 INFO [htknx.__main__|main_async]: Connected successfully to heat pump with serial number 123456.
2021-01-27 17:14:36,551 INFO [htknx.__main__|main_async]: Software version = 3.0.20 (2321)
2021-01-27 17:14:36,587 WARNING [xknx.log|loop_until_sigint]: Press Ctrl+C to stop
2021-01-27 17:14:36,592 INFO [htknx.__main__|login_loop]: <<< [ LOGIN (every 0:00:30) ] >>>
2021-01-27 17:14:36,598 INFO [htknx.__main__|update_loop]: <<< [ UPDATE (every 0:00:25) ] >>>
2021-01-27 17:14:36,604 INFO [htknx.__main__|cyclic_sending_loop]: <<< [ CYCLIC SENDING (every 0:01:00) ] >>>
2021-01-27 17:14:36,608 INFO [htknx.__main__|cyclic_sending_loop]: Sending: ['Temp. Aussen', 'Stoerung']
2021-01-27 17:14:37,152 INFO [htknx.__main__|update_loop]: Update: {'Betriebsart': 1, 'HKR Soll_Raum': 22.0, 'WW Normaltemp.': 50, 'BSZ Verdichter Betriebsst. ges': 12000, 'Temp. Aussen': -2.6, 'Temp. Frischwasser_Istwert': 43.6, 'Heizkreispumpe': True, 'Stoerung': False}
2021-01-27 17:14:37,156 INFO [htknx.htdatapoint|set]: Update and send DP 'Betriebsart' [1/7/9]: value=1 (send_on_change: True, on_change_of_absolute: 1, on_change_of_relative: None, last_sent_value: None)
2021-01-27 17:14:37,161 INFO [htknx.htdatapoint|set]: Update and send DP 'HKR Soll_Raum' [1/7/10]: value=22.0 (send_on_change: True, on_change_of_absolute: 0.1, on_change_of_relative: None, last_sent_value: None)
2021-01-27 17:14:37,165 INFO [htknx.htdatapoint|set]: Update and send DP 'WW Normaltemp.' [1/7/17]: value=50 (send_on_change: True, on_change_of_absolute: 1, on_change_of_relative: None, last_sent_value: None)
2021-01-27 17:14:37,170 INFO [htknx.htdatapoint|set]: Update and send DP 'Temp. Frischwasser_Istwert' [1/7/45]: value=43.6 (send_on_change: True, on_change_of_absolute: None, on_change_of_relative: 10, last_sent_value: None)
2021-01-27 17:15:02,181 INFO [htknx.__main__|update_loop]: <<< [ UPDATE (every 0:00:25) ] >>>
2021-01-27 17:15:02,633 INFO [htknx.__main__|update_loop]: Update: {'Betriebsart': 1, 'HKR Soll_Raum': 22.0, 'WW Normaltemp.': 50, 'BSZ Verdichter Betriebsst. ges': 12001, 'Temp. Aussen': -2.6, 'Temp. Frischwasser_Istwert': 43.6, 'Heizkreispumpe': True, 'Stoerung': False}
2021-01-27 17:15:06,641 INFO [htknx.__main__|login_loop]: <<< [ LOGIN (every 0:00:30) ] >>>
2021-01-27 17:15:27,662 INFO [htknx.__main__|update_loop]: <<< [ UPDATE (every 0:00:25) ] >>>
2021-01-27 17:15:28,107 INFO [htknx.__main__|update_loop]: Update: {'Betriebsart': 1, 'HKR Soll_Raum': 22.0, 'WW Normaltemp.': 50, 'BSZ Verdichter Betriebsst. ges': 12001, 'Temp. Aussen': -2.6, 'Temp. Frischwasser_Istwert': 43.6, 'Heizkreispumpe': True, 'Stoerung': False}
2021-01-27 17:15:36,624 INFO [htknx.__main__|cyclic_sending_loop]: <<< [ CYCLIC SENDING (every 0:01:00) ] >>>
2021-01-27 17:15:36,629 INFO [htknx.__main__|cyclic_sending_loop]: Sending: ['Temp. Aussen', 'Stoerung']
2021-01-27 17:15:36,688 INFO [htknx.__main__|login_loop]: <<< [ LOGIN (every 0:00:30) ] >>>
...
htknx is controlled via a configuration file. Per default the configuration file is named htknx.yaml.
The configuration file can contain the following five sections:
-
The
generalsection can contain:update_intervalthe update interval to refresh the heat pump parameters (optional, default:60seconds)cyclic_sending_intervalthe time interval for data points that are to be sent cyclically to the KNX bus (optional, default:10minutes)synchronize_clock_weeklyto define the day of the week (mon,tue,wed,thu,fri,sat,sun) and the time (e.g.'19:55') to synchronize the heat pump clock regularly (optional, default: disabled)
-
The
heat_pumpsection is needed to specify the connection to the heat pump:devicethe serial device on which the heat pump is connected (e.g./dev/ttyUSB0)baudratebaudrate of the serial connection to the heat pump (same as configured on the heat pump, e.g.19200)
-
The
knxsection is needed to specify the connection to the KNX interface (e.g. a Weinzierl KNX IP Interface 731):gateway_ipthe ip address of the KNX tunneling interface (e.g.192.168.11.81)gateway_portthe port the KNX tunneling interface is listening on (optional, default:3671)auto_reconnectdetermines whether to try a reconnect if the connection to the KNX tunneling interface could not be established (optional, default:true)auto_reconnect_waitthe time to wait for the next auto reconnect (optional, default:3seconds)local_ipthe local ip address that is used to connect to the KNX tunneling interface (optional, e.g.192.168.11.114)own_addressthe individual (physical) address of this gateway (optional, default:15.15.250)rate_limita rate limit for telegrams sent to the KNX bus per second (optional, default:10)
-
The
data_pointssection contains the dictionary of heat pump parameters for which a data point should be provided to the KNX bus.Each item in the dictionary consists of the "parameter name" as key and the following properties:
value_typethe value type of the data point (e.g.binary,common_temperature,1byte_unsigned,4byte_unsigned, etc. as supported by XKNX)group_addressthe KNX group address of the data point (e.g.1/2/3)writabledetermines whether the data point could also be written or not (optional, default:false)cyclic_sendingdetermines whether the data point should be sent cyclically to the KNX bus (optional, default:false)send_on_changedefines whether the data point should be sent to the KNX bus if it changes for a defined value (optional, default:false)on_change_of_absolutethe absolute value of change for sending on change (e.g.0.5for 0.5°C)on_change_of_relativethe relative value of change for sending on change (in percent, e.g.10for 10%)
A list of supported value types can be found in the comments of the configuration template or sample configuration file. These are exactly the same value types supported by the XKNX module on which this project is based.
-
The
notificationssection contains the setup of the different supported notifications (optional).At the moment the following notifications are supported:
-
on_malfunctionwhich sends a notification with the current error message (as DPT-16.000) to the KNX bus if the heat pump is malfunctioning:group_addressthe KNX group address under which the error message is sent (e.g.1/2/255)repeat_afterthe time interval until the notification should be repeated if the heat pump is still malfunctioning (optional, e.g.10minutes)
-
The following block shows a sample configuration for the heat pump parameters
- Betriebsart,
- HKR Soll_Raum,
- WW Normaltemp.,
- BSZ Verdichter Betriebsst. ges,
- Temp. Aussen,
- Temp. Frischwasser_Istwert,
- Heizkreispumpe and
- Stoerung.
These heat pump parameters are updated every 25 seconds and some of them are sent cyclically to the KNX bus every minute, while some of the other parameters are sent immediately after a change.
Only the three parameters "Betriebsart", "HKR Soll_Raum" and "WW Normaltemp." are writable.
In addition, a notification with the current error message is sent to the KNX bus if the heat pump is malfunctioning.
general:
update_interval:
seconds: 25
cyclic_sending_interval:
minutes: 1
# synchronize_clock_weekly:
# weekday: tue # mon, tue, wed, thu, fri, sat, sun
# time: '13:05'
heat_pump:
device: /dev/ttyUSB0
baudrate: 115200
knx:
gateway_ip: '192.168.11.81'
rate_limit: 10
# gateway_port: 3671
# auto_reconnect: True
# auto_reconnect_wait:
# seconds: 3
# local_ip: '192.168.11.140'
# own_address: '15.15.250'
data_points:
# https://htheatpump.readthedocs.io/en/latest/htparams.html
# -----------------------------------------------------------------
'Betriebsart':
# 0 = Aus
# 1 = Automatik
# 2 = Kühlen
# 3 = Sommer
# 4 = Dauerbetrieb
# 5 = Absenkung
# 6 = Urlaub
# 7 = Party
value_type: '1byte_unsigned' # DPT-5.005 (Dezimalfaktor 0..255)
group_address: '1/7/9'
writable: true
send_on_change: true
on_change_of_absolute: 1
# -----------------------------------------------------------------
'HKR Soll_Raum':
# MIN: 10.0
# MAX: 25.0
value_type: 'common_temperature' # DPT-14.068 (Temperatur °C)
group_address: '1/7/10'
writable: true
send_on_change: true
on_change_of_absolute: 0.1
# -----------------------------------------------------------------
'WW Normaltemp.':
# MIN: 10
# MAX: 75
value_type: '1byte_unsigned' # DPT-5.005 (Dezimalfaktor 0..255)
# or:
# value_type: 'common_temperature' # DPT-14.068 (Temperatur °C)
group_address: '1/7/17'
writable: true
send_on_change: true
on_change_of_absolute: 1
# -----------------------------------------------------------------
'BSZ Verdichter Betriebsst. ges':
# MIN: 0
# MAX: 100000
value_type: '4byte_unsigned' # DPT-12.102 (Zähler Zeit Stunden)
group_address: '1/7/31'
# -----------------------------------------------------------------
'Temp. Aussen':
# MIN: -20.0
# MAX: 40.0
value_type: 'common_temperature' # DPT-14.068 (Temperatur °C)
group_address: '1/7/36'
cyclic_sending: true
# -----------------------------------------------------------------
'Temp. Frischwasser_Istwert':
# MIN: 0.0
# MAX: 70.0
value_type: 'common_temperature' # DPT-14.068 (Temperatur °C)
group_address: '1/7/45'
send_on_change: true
on_change_of_relative: 10
# -----------------------------------------------------------------
'Heizkreispumpe':
# MIN: 0
# MAX: 1
value_type: 'binary' # DPT-1.011 (Status)
group_address: '1/7/51'
send_on_change: true
# -----------------------------------------------------------------
'Stoerung':
# MIN: 0
# MAX: 1
value_type: 'binary' # DPT-1.005 (Alarm)
group_address: '1/7/56'
cyclic_sending: true
notifications:
on_malfunction:
group_address: '1/7/255' # DPT-16.000 (Zeichen ASCII)
repeat_after:
minutes: 10
The following image shows a screenshot of the Group Monitor of the ETS application with the data points provided by the upper sample configuration: