File tree Expand file tree Collapse file tree 2 files changed +26
-2
lines changed
Expand file tree Collapse file tree 2 files changed +26
-2
lines changed Original file line number Diff line number Diff line change @@ -37,12 +37,15 @@ render:
3737 template: rct-power
3838 usage: battery
3939 host: 192.0.2.2 # IP-Adresse oder Hostname
40+ capacity: 50 # Akkukapazität (kWh), optional
41+ capacity2: 50 # Akkukapazität der zweiten Batterie (kWh), optional
4042 advanced : |
4143 type: template
4244 template: rct-power
4345 usage: battery
4446 host: 192.0.2.2 # IP-Adresse oder Hostname
4547 capacity: 50 # Akkukapazität (kWh), optional
48+ capacity2: 50 # Akkukapazität der zweiten Batterie (kWh), optional
4649 minsoc: 7 # Minimaler Ladestand (%), Untere Grenze beim Entladen der Batterie im normalen Betrieb (optional)
4750 maxsoc: 97 # Maximaler Ladestand (%), Oberes Limit beim Laden der Batterie aus dem Netz (optional)
4851 cache: 30s # Cache, Zeitintervall für erneute Datenabfrage (optional)
@@ -64,7 +67,16 @@ params:
6467 unit : kWh
6568 description : Akkukapazität
6669 help :
67- advanced : true
70+ advanced : false
71+ optional : true
72+ - name : capacity2
73+ example : 50
74+ default :
75+ choice : []
76+ unit : kWh
77+ description : Akkukapazität der zweiten Batterie
78+ help :
79+ advanced : false
6880 optional : true
6981 - name : minsoc
7082 example : 25
Original file line number Diff line number Diff line change @@ -37,12 +37,15 @@ render:
3737 template: rct-power
3838 usage: battery
3939 host: 192.0.2.2 # IP address or hostname
40+ capacity: 50 # Battery capacity (kWh), optional
41+ capacity2: 50 # Battery capacity of the second battery (kWh), optional
4042 advanced : |
4143 type: template
4244 template: rct-power
4345 usage: battery
4446 host: 192.0.2.2 # IP address or hostname
4547 capacity: 50 # Battery capacity (kWh), optional
48+ capacity2: 50 # Battery capacity of the second battery (kWh), optional
4649 minsoc: 7 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
4750 maxsoc: 97 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
4851 cache: 30s # Cache, Time interval for data refresh (optional)
@@ -64,7 +67,16 @@ params:
6467 unit : kWh
6568 description : Battery capacity
6669 help :
67- advanced : true
70+ advanced : false
71+ optional : true
72+ - name : capacity2
73+ example : 50
74+ default :
75+ choice : []
76+ unit : kWh
77+ description : Battery capacity of the second battery
78+ help :
79+ advanced : false
6880 optional : true
6981 - name : minsoc
7082 example : 25
You can’t perform that action at this time.
0 commit comments