This is a proposal for feature request #1325.

When an inverter has a safe limit timeout enabled, a new /api/limit/safe endpoint is enabled to enact limits safely.

The caller needs to ensure that the limit is confirmed before the timeout expires; otherwise, the limit is rolled back to the safe limit value.

@unaiur unaiur force-pushed the safe-limits-v1 branch 2 times, most recently from 282ea23 to abe69b3 Compare September 18, 2023 19:49
When an inverter has the safe limit timeout enabled, a new /api/limit/safe WebApi
is enabled that allow to setup dynamic non-persistent limits.

Those dynamic limits are reverted if they are not confirmed periodically before the
safe limit timeout expires.

This way, if the controller or the WiFi router dies, the limit is safely restored
to the default limit.
@RobertLukan
Copy link

This is a very good feature. Do you think it will get merged ?

@stefan123t
Copy link
Contributor

@unaiur maybe it would be a good idea to add this PR to OpenDTU-OnBattery as it would be more fitting there ?

This is similar to a "hard" temporary limit, which will be used as a fallback after N minutes of idle time,
i.e. no updated temporary limit or otherwise a heartbeat from the external / internal (dynamic) limit controller will send the safe fallback limit to prevent e.g. deep decharge of a battery powered system.
See #1093 for another change to the Limit API making it more robust.

@unaiur